Entity supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature #200

Open
JeroenTogt opened this issue Aug 19, 2024 · 0 comments

Comments

@JeroenTogt
Copy link

HVAC modes are not the actual modes the FAN is capable of
FAN is Itho CVE-S ECO

Warning in the log file during start:

2024-08-17 18:40:13.470 WARNING (MainThread) [homeassistant.components.climate] Entity climate.37:252531 (<class 'custom_components.ramses_cc.climate.RamsesHvac'>) implements HVACMode(s): auto, off and therefore implicitly supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature. Please create a bug report at https://github.com/zxdavb/ramses_cc/issues

Usage case is the following:

  1. Setting modes of fan 37:252531 with the fysical remote 37:012161, both fan and remote are a "37"
  2. Setting modes with faked remote with same id as fysical remote
  3. Automation that switces fan on via a zwave plug and repeats the command as with putting power on the FAN the fan starts always in auto mode.

The way I have implemented works fine but obviously the controls that are made for the FAN entity are not working and it does give the warning in the LOG..

For me just a nuisance in the log, but there are probably some tweeks to fix it or recognize the Itho CVE-S ECO

Relevant part of Schema:

orphans_hvac:
  - "37:012161"
  - "37:252531"

Relevant part of know device id's

"37:012161":
  class: REM
  faked: true
  commands:
    Auto_Mode: " I --- 37:012161 37:252531 --:------ 22F1 003 000304"
    Laag_Stand: " I --- 37:012161 37:252531 --:------ 22F1 003 000204"
    Hoog_Stand: " I --- 37:012161 37:252531 --:------ 22F1 003 000404"
    10Min_Hoog: " I --- 37:012161 37:252531 --:------ 22F3 003 00000A"
    20Min_Hoog: " I --- 37:012161 37:252531 --:------ 22F3 003 000014"
    30Min_Hoog: " I --- 37:012161 37:252531 --:------ 22F3 003 00001E"
  _note: based upon RFT-N Auto with itho cve-s eco
"37:252531":
  class: FAN
  _note: Itho CVE-S ECO

@zxdavb zxdavb changed the title Entity xxx implements HVACMode(s): auto, off and therefore implicitly supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature. Entity implicitly supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature. Aug 19, 2024
@zxdavb zxdavb changed the title Entity implicitly supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature. Entity supports the turn_on/turn_off methods without setting the proper ClimateEntityFeature Aug 19, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

1 participant