-
Notifications
You must be signed in to change notification settings - Fork 0
/
gcode.h
198 lines (159 loc) · 6.9 KB
/
gcode.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
/*
gcode.h - rs274/ngc parser.
Part of Grbl v0.9
Copyright (c) 2012-2014 Sungeun K. Jeon
Grbl is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
Grbl is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with Grbl. If not, see <http://www.gnu.org/licenses/>.
*/
/*
This file is based on work from Grbl v0.8, distributed under the
terms of the MIT-license. See COPYING for more details.
Copyright (c) 2009-2011 Simen Svale Skogsrud
Copyright (c) 2011-2012 Sungeun K. Jeon
*/
#ifndef gcode_h
#define gcode_h
// Define modal group internal numbers for checking multiple command violations and tracking the
// type of command that is called in the block. A modal group is a group of g-code commands that are
// mutually exclusive, or cannot exist on the same line, because they each toggle a state or execute
// a unique motion. These are defined in the NIST RS274-NGC v3 g-code standard, available online,
// and are similar/identical to other g-code interpreters by manufacturers (Haas,Fanuc,Mazak,etc).
// NOTE: Modal group define values must be sequential and starting from zero.
#define MODAL_GROUP_G0 0 // [G4,G10,G28,G28.1,G30,G30.1,G53,G92,G92.1] Non-modal
#define MODAL_GROUP_G1 1 // [G0,G1,G2,G3,G38.2,G80] Motion
#define MODAL_GROUP_G2 2 // [G17,G18,G19] Plane selection
#define MODAL_GROUP_G3 3 // [G90,G91] Distance mode
#define MODAL_GROUP_G5 4 // [G93,G94] Feed rate mode
#define MODAL_GROUP_G6 5 // [G20,G21] Units
#define MODAL_GROUP_G8 6 // [G43,G43.1,G49] Tool length offset
#define MODAL_GROUP_G12 7 // [G54,G55,G56,G57,G58,G59] Coordinate system selection
#define MODAL_GROUP_M4 8 // [M0,M1,M2,M30] Stopping
#define MODAL_GROUP_M7 9 // [M3,M4,M5] Spindle turning
#define MODAL_GROUP_M8 10 // [M7,M8,M9] Coolant control
#define OTHER_INPUT_F 11
#define OTHER_INPUT_S 12
#define OTHER_INPUT_T 13
// Define command actions for within execution-type modal groups (motion, stopping, non-modal). Used
// internally by the parser to know which command to execute.
// Modal Group G0: Non-modal actions
#define NON_MODAL_NO_ACTION 0 // (Default: Must be zero)
#define NON_MODAL_DWELL 1 // G4
#define NON_MODAL_SET_COORDINATE_DATA 2 // G10
#define NON_MODAL_GO_HOME_0 3 // G28
#define NON_MODAL_SET_HOME_0 4 // G28.1
#define NON_MODAL_GO_HOME_1 5 // G30
#define NON_MODAL_SET_HOME_1 6 // G30.1
#define NON_MODAL_ABSOLUTE_OVERRIDE 7 // G53
#define NON_MODAL_SET_COORDINATE_OFFSET 8 // G92
#define NON_MODAL_RESET_COORDINATE_OFFSET 9 //G92.1
// Modal Group G1: Motion modes
#define MOTION_MODE_SEEK 0 // G0 (Default: Must be zero)
#define MOTION_MODE_LINEAR 1 // G1
#define MOTION_MODE_CW_ARC 2 // G2
#define MOTION_MODE_CCW_ARC 3 // G3
#define MOTION_MODE_PROBE 4 // G38.2
#define MOTION_MODE_NONE 5 // G80
// Modal Group G2: Plane select
#define PLANE_SELECT_XY 0 // G17 (Default: Must be zero)
#define PLANE_SELECT_ZX 1 // G18
#define PLANE_SELECT_YZ 2 // G19
// Modal Group G3: Distance mode
#define DISTANCE_MODE_ABSOLUTE 0 // G90 (Default: Must be zero)
#define DISTANCE_MODE_INCREMENTAL 1 // G91
// Modal Group M4: Program flow
#define PROGRAM_FLOW_RUNNING 0 // (Default: Must be zero)
#define PROGRAM_FLOW_PAUSED 1 // M0, M1
#define PROGRAM_FLOW_COMPLETED 2 // M2, M30
// Modal Group G5: Feed rate mode
#define FEED_RATE_MODE_UNITS_PER_MIN 0 // G94 (Default: Must be zero)
#define FEED_RATE_MODE_INVERSE_TIME 1 // G93
// Modal Group G6: Units mode
#define UNITS_MODE_MM 0 // G21 (Default: Must be zero)
#define UNITS_MODE_INCHES 1 // G20
// Modal Group M7: Spindle control
#define SPINDLE_DISABLE 0 // M5 (Default: Must be zero)
#define SPINDLE_ENABLE_CW 1 // M3
#define SPINDLE_ENABLE_CCW 2 // M4
// Modal Group M8: Coolant control
#define COOLANT_DISABLE 0 // M9 (Default: Must be zero)
#define COOLANT_MIST_ENABLE 1 // M7
#define COOLANT_FLOOD_ENABLE 2 // M8
// Modal Group G8: Tool length offset
#define TOOL_LENGTH_OFFSET_CANCEL 0 // G49 (Default: Must be zero)
#define TOOL_LENGTH_OFFSET_ENABLE_DYNAMIC 1 // G43.1
// Modal Group G12: Active work coordinate system
// N/A: Stores coordinate system value (54-59) to change to.
#define WORD_F 0
#define WORD_I 1
#define WORD_J 2
#define WORD_K 3
#define WORD_L 4
#define WORD_N 5
#define WORD_P 6
#define WORD_R 7
#define WORD_S 8
#define WORD_T 9
#define WORD_X 10
#define WORD_Y 11
#define WORD_Z 12
// NOTE: When this struct is zeroed, the above defines set the defaults for the system.
typedef struct {
uint8_t motion; // {G0,G1,G2,G3,G38.2,G80}
uint8_t feed_rate; // {G93,G94}
uint8_t units; // {G20,G21}
uint8_t distance; // {G90,G91}
uint8_t plane_select; // {G17,G18,G19}
uint8_t tool_length; // {G43.1,G49}
uint8_t coord_select; // {G54,G55,G56,G57,G58,G59}
uint8_t program_flow; // {M0,M1,M2,M30}
uint8_t coolant; // {M7,M8,M9}
uint8_t spindle; // {M3,M4,M5}
} gc_modal_t;
typedef struct {
float f; // Feed
float ijk[3]; // I,J,K Axis arc offsets
uint8_t l; // G10 or canned cycles parameters
int32_t n; // Line number
float p; // G10 or dwell parameters
// float q; // G82 peck drilling
float r; // Arc radius
float s; // Spindle speed
uint8_t t; // Tool selection
float xyz[3]; // X,Y,Z Translational axes
} gc_values_t;
typedef struct {
gc_modal_t modal;
float spindle_speed; // RPM
float feed_rate; // Millimeters/min
uint8_t tool; // Tracks tool number. NOT USED.
float position[N_AXIS]; // Where the interpreter considers the tool to be at this point in the code
float coord_system[N_AXIS]; // Current work coordinate system (G54+). Stores offset from absolute machine
// position in mm. Loaded from EEPROM when called.
float coord_offset[N_AXIS]; // Retains the G92 coordinate offset (work coordinates) relative to
// machine zero in mm. Non-persistent. Cleared upon reset and boot.
float tool_length_offset; // Tracks tool length offset value when enabled.
} parser_state_t;
extern parser_state_t gc_state;
typedef struct {
// uint16_t command_words; // NOTE: If this bitflag variable fills, G and M words can be separated.
// uint16_t value_words;
uint8_t non_modal_command;
gc_modal_t modal;
gc_values_t values;
} parser_block_t;
extern parser_block_t gc_block;
// Initialize the parser
void gc_init();
// Execute one block of rs275/ngc/g-code
uint8_t gc_execute_line(char *line);
// Set g-code parser position. Input in steps.
void gc_sync_position();
#endif