-
Notifications
You must be signed in to change notification settings - Fork 29
/
ACD-ALARM-MIB.mib
510 lines (446 loc) · 16.9 KB
/
ACD-ALARM-MIB.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
--
-- Accedian Enterprise Specific MIB: Structure of Management Information
--
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
ACD-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI
DisplayString, TruthValue, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
sysName
FROM SNMPv2-MIB
acdMibs
FROM ACCEDIAN-SMI;
acdAlarm MODULE-IDENTITY
LAST-UPDATED "201110100100Z"
ORGANIZATION "Accedian Networks, Inc."
CONTACT-INFO
"Accedian Technical Assistance Center
Accedian Networks, Inc.
2351 Alfred-Nobel blvd., Suite N-410
Saint-Laurent, Quebec Canada H4S 2A9
E-mail: [email protected]"
DESCRIPTION
"The alarm Table for this Accedian Networks device."
REVISION "201110100100Z" -- 10 October 2011
DESCRIPTION
"Add acdAlarmCfgTableLastChangeTid and
acdAlarmStatusTableLastChangeTid."
REVISION "201011100100Z" -- 10 November 2010
DESCRIPTION
"Fix compliance section."
REVISION "200902040100Z" -- 4 Feb 2009
DESCRIPTION
"Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and
acdAlarmClearState."
REVISION "200802010100Z" -- 1 Feb 2008
DESCRIPTION
"Add UNITS clause to object, where appropriate."
REVISION "200705220100Z" -- 22 May 2007
DESCRIPTION
"Add acdAlarmCfgNumber object to Alarm traps."
REVISION "200612190100Z" -- 19 Dec 2006
DESCRIPTION
"Add 802.3AH notification enable and msg field in status table."
REVISION "200608060100Z" -- 6 Aug 2006
DESCRIPTION
"Initial version of MIB module ACD-ALARM-MIB."
::= { acdMibs 1 }
acdAlarmMIBObjects OBJECT IDENTIFIER ::= { acdAlarm 15 }
acdAlarmConfig OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 }
acdAlarmStatus OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 }
acdAlarmConformance OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 }
acdAlarmTableTid OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 }
---------------------------------------------------------------------------
-- Alarm General configuration
---------------------------------------------------------------------------
acdAlarmGenThreshOn OBJECT-TYPE
SYNTAX Unsigned32 (500..50000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents the Alarm On Hysteris. This is the time since the
detection of the On event inside the system versus the report. This is
to avoid storm of notifications."
::= { acdAlarm 1 }
acdAlarmGenThreshOff OBJECT-TYPE
SYNTAX Unsigned32 (500..50000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents the Alarm Off Hysteris. This is the time since the
detection of the Off event inside the system versus the report. This is
to avoid storm of notifications."
::= { acdAlarm 2 }
acdAlarmGenLedEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the LEDs."
::= { acdAlarm 3 }
acdAlarmGenSyslogEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the syslog system."
::= { acdAlarm 4 }
acdAlarmGenSNMPEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the SNMP agent."
::= { acdAlarm 5 }
acdAlarmGen8023AHEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the 802.3AH protocol."
::= { acdAlarm 6 }
---------------------------------------------------------------------------
-- The Alarm configuration table
-- This table contains the configuration for each alarm.
---------------------------------------------------------------------------
acdAlarmCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdAlarmCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all alarms."
::= { acdAlarm 10 }
acdAlarmCfgEntry OBJECT-TYPE
SYNTAX AcdAlarmCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm is an exceptional event that requires user notificaton."
INDEX { acdAlarmCfgID }
::= { acdAlarmCfgTable 1 }
AcdAlarmCfgEntry ::= SEQUENCE {
acdAlarmCfgID Unsigned32,
acdAlarmCfgNumber Unsigned32,
acdAlarmCfgDesc DisplayString,
acdAlarmCfgEnable TruthValue,
acdAlarmCfgSeverity INTEGER,
acdAlarmCfgServiceAffecting TruthValue,
acdAlarmCfgExtNumber DisplayString,
acdAlarmCfgConditionType DisplayString,
acdAlarmCfgAMOType DisplayString
}
acdAlarmCfgID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdAlarmCfgEntry 1 }
acdAlarmCfgNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.BBB.CC and is expressed in decimal, A is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8."
::= { acdAlarmCfgEntry 2 }
acdAlarmCfgDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is to describe the alarm in a readable way, e.g.:
+5Vdc Power supply fail."
::= { acdAlarmCfgEntry 3 }
acdAlarmCfgEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to indicate if the alarm is reported or not."
::= { acdAlarmCfgEntry 4 }
acdAlarmCfgSeverity OBJECT-TYPE
SYNTAX INTEGER {
info(0),
minor(1),
major(2),
critical(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Accedian Networks classifies alarms into four severity types. These types
and their associated decimal codes are, informational(0), minor(1),
major(2) and critical(3)."
::= { acdAlarmCfgEntry 5 }
acdAlarmCfgServiceAffecting OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to indicate if the alarm is service affecting or not. This
value depends on the utilization of the box. For instance in an
application where the monitoring of the traffic is mandatory the link
down event on the monitor port is service affecting."
::= { acdAlarmCfgEntry 6 }
acdAlarmCfgExtNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.B.C and is expressed in decimal, A is the module number, B is
the instance number and C is the error number. A module number is
assigned for each source of alarm in the system (see Accedian
documentation for more detail)."
::= { acdAlarmCfgEntry 7 }
acdAlarmCfgConditionType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the type of alarm condition."
::= { acdAlarmCfgEntry 8 }
acdAlarmCfgAMOType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the Alarm Maintenance Object."
::= { acdAlarmCfgEntry 9 }
---------------------------------------------------------------------------
-- The Alarms Status table
-- This table contains the status of all alarms.
---------------------------------------------------------------------------
acdAlarmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdAlarmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all alarms"
::= { acdAlarm 11 }
acdAlarmStatusEntry OBJECT-TYPE
SYNTAX AcdAlarmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm is an exceptional event that requires user notificaton."
INDEX { acdAlarmStatusID }
::= { acdAlarmStatusTable 1 }
AcdAlarmStatusEntry ::= SEQUENCE {
acdAlarmStatusID Unsigned32,
acdAlarmStatusNumber Unsigned32,
acdAlarmStatusOn TruthValue,
acdAlarmStatusLastChange DateAndTime,
acdAlarmStatusMsg DisplayString
}
acdAlarmStatusID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdAlarmStatusEntry 1 }
acdAlarmStatusNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8."
::= { acdAlarmStatusEntry 2 }
acdAlarmStatusOn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the alarm is On or Off."
::= { acdAlarmStatusEntry 3 }
acdAlarmStatusLastChange OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the time of the last change for this alarm. A value of zero
means that nothing happened to this alarm since the last reboot."
::= { acdAlarmStatusEntry 4 }
acdAlarmStatusMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string is to add information why the alarm is reported."
::= { acdAlarmStatusEntry 5 }
-- Accedian Alarm Traps
---------------------------------------------------------------------------
-- DESCRIPTION "Definition point for Accedian Alarm notifications."
---------------------------------------------------------------------------
acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 }
acdAlarmActiveState NOTIFICATION-TYPE
OBJECTS { acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgDesc,
acdAlarmStatusLastChange,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType,
sysName }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps."
::= { acdAlarmV2 1 }
acdAlarmClearState NOTIFICATION-TYPE
OBJECTS { acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgDesc,
acdAlarmStatusLastChange,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType,
sysName }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps."
::= { acdAlarmV2 2 }
---------------------------------------------------------------------------
-- Transaction ID Information
---------------------------------------------------------------------------
acdAlarmCfgTableLastChangeTid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the transaction ID of the last change of the acdAlarmCfgTable
table. If this value is different since the last read this is indicate
a table change."
::= { acdAlarmTableTid 1 }
acdAlarmStatusTableLastChangeTid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the transaction ID of the last change of the acdAlarmStatusTable
table. If this value is different since the last read this is indicate
a table change."
::= { acdAlarmTableTid 2 }
---------------------------------------------------------------------------
-- ACD-ALARM-MIB Module - Conformance Information
---------------------------------------------------------------------------
acdAlarmCompliances OBJECT IDENTIFIER ::= { acdAlarmConformance 1 }
acdAlarmGroups OBJECT IDENTIFIER ::= { acdAlarmConformance 2 }
---------------------------------------------------------------------------
-- Units of conformance
---------------------------------------------------------------------------
acdAlarmGenGroup OBJECT-GROUP
OBJECTS {
acdAlarmGenThreshOn,
acdAlarmGenThreshOff,
acdAlarmGenLedEnable,
acdAlarmGenSyslogEnable,
acdAlarmGenSNMPEnable,
acdAlarmGen8023AHEnable
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 1 }
acdAlarmCfgGroup OBJECT-GROUP
OBJECTS {
acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgDesc,
acdAlarmCfgEnable,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 2 }
acdAlarmStatusGroup OBJECT-GROUP
OBJECTS {
acdAlarmStatusID,
acdAlarmStatusNumber,
acdAlarmStatusOn,
acdAlarmStatusLastChange,
acdAlarmStatusMsg
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 3 }
acdAlarmNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
acdAlarmActiveState,
acdAlarmClearState
}
STATUS current
DESCRIPTION
"Objects for the Notifications group."
::= { acdAlarmGroups 4 }
acdAlarmTidGroup OBJECT-GROUP
OBJECTS {
acdAlarmCfgTableLastChangeTid,
acdAlarmStatusTableLastChangeTid
}
STATUS current
DESCRIPTION
"List of scalars to monitior changes in tables."
::= { acdAlarmGroups 5 }
---------------------------------------------------------------------------
-- MIB Module Compliance statements
---------------------------------------------------------------------------
acdAlarmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support of the ACD-ALARM-MIB module."
MODULE
MANDATORY-GROUPS {
acdAlarmGenGroup,
acdAlarmCfgGroup,
acdAlarmStatusGroup,
acdAlarmNotificationsGroup,
acdAlarmTidGroup
}
::= { acdAlarmCompliances 1 }
END