RCA - BK: Hoyt St/5th St #95

Open
ak6492 opened this issue Feb 12, 2024 · 1 comment
Open

RCA - BK: Hoyt St/5th St #95

ak6492 opened this issue Feb 12, 2024 · 1 comment
Assignees
Labels
fault_failed_battery Battery failed - doesnt hold charge, doesnt charge

Comments

@ak6492
Copy link
Contributor

ak6492 commented Feb 12, 2024

Sensor Deployed:
October 5, 2020 by FloodNet

Sensor Version:

Firmware Version:

replace battery. trended downward. been out in field for two years

@ak6492
Copy link
Contributor Author

ak6492 commented Feb 13, 2024

02/13: Sensor has magically come back up recharged. Keep an eye out and monitor battery level

Screenshot 2024-02-13 at 3 22 40 PM

@ak6492 ak6492 self-assigned this Feb 13, 2024
@ak6492 ak6492 added the fault_failed_battery Battery failed - doesnt hold charge, doesnt charge label Feb 13, 2024