RCA - BK: Junius St/ Sutter Ave #76

Open
ak6492 opened this issue Aug 18, 2023 · 1 comment
Open

RCA - BK: Junius St/ Sutter Ave #76

ak6492 opened this issue Aug 18, 2023 · 1 comment
Labels
fault_no_return maxbotix is hitting invalid values

Comments

@ak6492
Copy link
Contributor

ak6492 commented Aug 18, 2023

Sensor Deployed:
May 24, 2023 by FloodNet

Sensor Version: 2.5

Firmware Version:

Sensor Down:
July 26, 2023 12:56 permanently down, but data has been spotty and inconsistent since the sensor has been deployed

BK - Junius St_Sutter Ave_Flood Depth

deployment_id: lovely_helped_lamb

@ak6492 ak6492 added the fault_no_return maxbotix is hitting invalid values label Sep 1, 2023
@ak6492
Copy link
Contributor Author

ak6492 commented Sep 1, 2023

Maintenance Trip on 08/17. Replaced heltec and battery was shorting. Went down again 08/28. Sensor was working fine but was back into config mode. Went back out on 08/31 and reprogrammed the sensor. We think the config issue might be do to some error in firmware. Downloaded and uploaded the latest firmware. This sensor is also noisy. Might be do it being mounted at 3meters which is relatively higher than usual sensors. As distance increases the maxbotix has more room for error. Need to observe this sensor a little more and might need to change its mounting distance.