The gateway also has a little web interface, which shows it's network configuration. There is no direct way to configure the device with this web interface. However the values in bold can be modified via a UDP interface.
Mobile Alerts Settings & States
Software: MOBILE-ALERTS-Gateway V1.50.00
Compilation Date: 02/11/15
Compilation Time: 10:50:00
Serial No. (hex.): 80AABBCC
Serial No. (dec.): 00 11 22 33
Name: MOBILEALERTS-Gateway
Registration state: Registered
Use DHCP: Yes
Fixed IP: 192.168.1.222
Fixed Netmask: 255.255.255.0
Fixed Gateway: 192.168.1.254
Fixed DNS IP: 192.168.1.253
DHCP valid: Yes
DHCP IP: 192.168.1.100
DHCP Netmask: 255.255.255.0
DHCP Gateway: 192.168.1.1
DHCP DNS: 192.168.1.1
DNS states: 0 / 0
Data Server Name: www.data199.com
Use Proxy: No
Proxy Server Name: 192.168.1.1
Proxy Port: 8080
Proxy Server IP: 192.168.1.1
Last contact: No contact
RF channel: 2
Go to MOBILE-ALERTS - Homepage
Time:686300
Serial No. (hex.)
is "80" plus the lower 3 bytes of the ID converted to hex. Serial No. (dec.)
is the same, with the lower 3 bytes treated as a single number converted to decimal and with spaces every 2 digits resulting in 8 decimal digits.
Last contact
is a UTC UNIX timestamp in a ms resolution from the last time the gateway contacted the cloud server.
The Time
on the webpage is the number of microseconds since boot divided by 100. Or – if you prefer it this way – the number of seconds plus 4 additional digits with sub-seconds resolution with the lowest 2 always being 0.