Intensity of optogenetic stimulus? #6

Closed
CodyCBakerPhD opened this issue Apr 1, 2024 · 4 comments
Closed

Intensity of optogenetic stimulus? #6

CodyCBakerPhD opened this issue Apr 1, 2024 · 4 comments
Assignees

Comments

@CodyCBakerPhD
Copy link
Member

Details are given for intensity of the calcium imaging in the methods section, but not for the optogenetic stimulation

@CodyCBakerPhD CodyCBakerPhD self-assigned this Apr 1, 2024
@emosb
Copy link

emosb commented Apr 1, 2024

I can measure this to check that it is still accurate, but in the methods of the Randi paper it is reported that "the power of the laser at the sample was 1.2 mW at 500 kHz" which is referring to the optogenetic stimulus laser pulse

@CodyCBakerPhD
Copy link
Member Author

CodyCBakerPhD commented Apr 1, 2024

@emosb That is the power, which I am indeed using - the intensity would be something in mW/mm^2, like in the paragraph from the methods section

For functional connectivity experiments, an intensity of 1.4 mW mm−2 at the sample plane was used to image GCaMP6s...

@CodyCBakerPhD
Copy link
Member Author

@emosb Unless you're saying the intensity is the same in the ogen case as in the imaging case because it's the same laser?

@CodyCBakerPhD
Copy link
Member Author

Leaving this empty since it would be too complicated and not worthwhile to report