Gate RTion project
The OpenGATE collaboration is willing to help clinical users setting-up GATE into the clinics. We are currently about 6 different ion therapy centers using, or about to use, GATE for clinical purposes.
- Providing a stable and long term GATE release, called GATE-RTion, having all necessary features for dosimetric applications in Light Ion Beam Therapy facilities equipped with the Pencil Beam Scanning delivery technique.
- Providing a collection of tools necessary for the clinical users to interface GATE with the clinical environment
- Developing guidelines for clinical users on how to implement GATE into the clinical routine using the provided tools
We plan to release the first version of GATE-RTion by the end of 2017 with all proton functionalities validated. Further releases will include carbon ion functionalities and other features.
LIBT facility | City | Country | Representatives |
---|---|---|---|
MedAustron | Wiener Neustadt | Austria | Loïc Grevillot, Alessio Elia, Antonio Carlino, Hermann Fuchs |
Skandion | Uppsala | Sweden | David Boersma, Erik Almhagen |
CPO | Orsay | France | Ludovic De Marzi |
CAL | Nice | France | Marie Vidal |
The Christie Fundation Trust | Manchster | UK | Adam Aitkenhead |
UCL / UCLH | London | UK | Andrea Gutierrez, Vasilis Rompokos, Tracy Underwood |
CREATIS lab | Lyon | France | David Sarrut |
Functionality | Current issue | Ticket (GitHub bug tracker) | Status | Priority | Proposals | Who? | Deadline |
---|---|---|---|---|---|---|---|
TPSPencilBeam source modeling | Rotational issues between beam and Couch | #84 | Done (Pull request #138) | 1 | Step1. proposal to remove couch rotation from the TPS source, so that TPS-source only account for gantry rotation, as images can be rotated anyhow. | Loïc Grevillot | Oct. 2017 |
TPSPencilBeam source modeling | Absolute calibration in MU | Done (Pull request #138) | 1 | new feature / code cleaning | Loïc Grevillot | Oct. 2017 | |
DoseToWater conversion | code cleaning for all particles till Protons | #104 | Done (Pull request #144) | 1 | To be investigated and fixed | Hermann Fuchs | Oct. 2017 |
RangeShifter overlap on CT geometries | new (Ludo input) | - | Done | 1 | David S. propsoed a new actor | David Sarrut | Oct. 2017 |
Functionality | Current issue | Ticket (GitHub bug tracker) | Status | Priority | Proposals | Who? | Deadline |
---|---|---|---|---|---|---|---|
HU to density/composition | interpolation issue | #37 | Open | 2 | To be investigated and fixed | Adam? David B. (with student) | TBD |
TPSPencilBeam source modeling | JASON file implementation | Open | 2 | new feature | David Sarrut/David Boersma | TBD |
Test Name | Type of test | Description | Status | priority | Who? | Deadline |
---|---|---|---|---|---|---|
TPSPencilBeam source | Functional testing (acceptance) | Verifying that the spot positions at isocenter and number of particles delivered are as planned; and that the beam optics and energy properties are as set in the source file. | Done (Pull request #12 -GateContrib) | 1 | Loïc Grevillot | Oct. 2017 |
DoseActor | Functional testing (acceptance) | Verifying that the energy/dose/dose-to-water are scored correctly for non-voxelized and voxelized geometries. | Open | 1 | Hermann Fuchs | Oct. 2017 |
CT modeling | Functional testing (acceptance) | Verifying the correspondance between HUs and tissue compositions and densities | Open | 1 | Adam? David B. (with student) | Dec. 2017 |
Patient positionning | Functional testing (acceptance) | Verifying that DICOM image can be adjusted correctly in terms of pitch/roll/jaw and translations x/y/z | Open | 1 | Erik/Marie | Dec. 2017 |
TPS validation workflow with range shifter | Functional testing (acceptance) | Validation of the TPS plan recalculation workflow based on a treatment plan exported from the TPS and simulated into GATE when the RS geometry overlap with the DICOM image | Open | 1 | Ludovic De Marzi | Dec. 2017 |
The Open Resources for GATE Monte Carlo simulations (Open-ReGate) platform will be used to share and document all necessary Tools, including guidelines. https://public.kitware.com/open-regate/index.php/Main_Page
The proposed release plan below provides only the main objectives:
- GATE-RTion V 1.0: all necessary features for dosimetric applications in Light Ion Beam Therapy facilities equipped with the Pencil Beam Scanning delivery technique for Protons + a set of Tools for the user
- GATE-RTion V2.0: Extension of V1.0 to carbon ion delivery
New functionalities provided by the members of the OpenGATE collaboration will be available in the standard GATE release, however they will only be part of a new GATE-RTion release if clinical user interest is raised and common effort agreed with the uses to validate the features. The developments listed below have been identified of potentially interest for the clinical users in future:
- RBE modeling and implementation of the MKM model (Lydia Maigne)
- 4D simulations including 4D CT and 4D treatment delivery (David Boersma)