title | description | addedAt | pageClass |
---|---|---|---|
Immax 07573L control via MQTT |
Integrate your Immax 07573L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2024-09-01 05:39:25 -0700 |
device-page |
Model | 07573L |
Vendor | Immax |
Description | Smart circuit breaker |
Exposes | linkquality, temperature, temperature_threshold, temperature_breaker, power_threshold, power_breaker, over_current_threshold, over_current_breaker, over_voltage_threshold, over_voltage_breaker, under_voltage_threshold, under_voltage_breaker, switch (state), power_outage_memory, indicator_mode, power, current, voltage, energy |
Picture |
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number. -
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.
Measured temperature value.
Value can be found in the published state on the temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
High temperature threshold.
Value can be found in the published state on the temperature_threshold
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_threshold": NEW_VALUE}
.
The minimal value is 40
and the maximum value is 100
.
The unit of this value is *C
.
High temperature breaker.
Value can be found in the published state on the temperature_breaker
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_breaker": NEW_VALUE}
.
If value equals ON
temperature breaker is ON, if OFF
OFF.
High power threshold.
Value can be found in the published state on the power_threshold
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_threshold": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 26
.
The unit of this value is kW
.
High power breaker.
Value can be found in the published state on the power_breaker
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_breaker": NEW_VALUE}
.
If value equals ON
power breaker is ON, if OFF
OFF.
Over-current threshold.
Value can be found in the published state on the over_current_threshold
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_current_threshold": NEW_VALUE}
.
The minimal value is 1
and the maximum value is 64
.
The unit of this value is A
.
Over-current breaker.
Value can be found in the published state on the over_current_breaker
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_current_breaker": NEW_VALUE}
.
If value equals ON
over current breaker is ON, if OFF
OFF.
Over-voltage threshold.
Value can be found in the published state on the over_voltage_threshold
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_voltage_threshold": NEW_VALUE}
.
The minimal value is 220
and the maximum value is 265
.
The unit of this value is V
.
Over-voltage breaker.
Value can be found in the published state on the over_voltage_breaker
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"over_voltage_breaker": NEW_VALUE}
.
If value equals ON
over voltage breaker is ON, if OFF
OFF.
Under-voltage threshold.
Value can be found in the published state on the under_voltage_threshold
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"under_voltage_threshold": NEW_VALUE}
.
The minimal value is 76
and the maximum value is 240
.
The unit of this value is V
.
Under-voltage breaker.
Value can be found in the published state on the under_voltage_breaker
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"under_voltage_breaker": NEW_VALUE}
.
If value equals ON
under voltage breaker is ON, if OFF
OFF.
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on.
Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands.
Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work
Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Recover state after power outage.
Value can be found in the published state on the power_outage_memory
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_outage_memory": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_outage_memory": NEW_VALUE}
.
The possible values are: on
, off
, restore
.
LED indicator mode.
Value can be found in the published state on the indicator_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"indicator_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"indicator_mode": NEW_VALUE}
.
The possible values are: off
, off/on
, on/off
, on
.
Instantaneous measured power.
Value can be found in the published state on the power
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.