Skip to content

Latest commit

 

History

History
53 lines (37 loc) · 2.81 KB

02973.B.md

File metadata and controls

53 lines (37 loc) · 2.81 KB
title description addedAt pageClass
Vimar 02973.B control via MQTT
Integrate your Vimar 02973.B via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2022-11-01 09:06:49 -0700
device-page

Vimar 02973.B

Model 02973.B
Vendor Vimar
Description Vimar IoT thermostat
Exposes climate (occupied_heating_setpoint, occupied_cooling_setpoint, local_temperature, system_mode), linkquality
Picture Vimar 02973.B

Options

How to use device type specific configuration

  • thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one of celsius, fahrenheit

Exposes

Climate

This climate device supports the following features: occupied_heating_setpoint, occupied_cooling_setpoint, local_temperature, system_mode.

  • occupied_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_heating_setpoint": VALUE} where VALUE is the °C between 4 and 40. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_heating_setpoint": ""}.
  • occupied_cooling_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_cooling_setpoint": VALUE} where VALUE is the °C between 4 and 40. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_cooling_setpoint": ""}.
  • local_temperature: Current temperature measured on the device (in °C). To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: off, heat, cool. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"system_mode": ""}.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.